Enhancements of Scout Enterprise Management Suite 15.5.1000 LTSR
- Incorrect processing of the device name template for newly generated devices and OU subnet filter redirection to a non-existing OU has been fixed
- Processing of the object right settings for Activate/Lock configuration transfer has been corrected
- USB recovery stick created by ELIAS based on a user-defined image works fine again on UEFI devices
- Updated code signing certificates and corresponding certificate chain in ELIAS
Enhancements of Scout Enterprise ELIAS 18.1.0
Improved usability and user experience such as
- Creating new containers / Click button to name container after eLux version to support container macro for installations with multiple eLux versions
- Importing software packages / Comfortable import process with extensive feedback and reports
- Exporting images / Various options and different formats
- Saving images or templates as a copy
Enhancements of eLux RP 6.5.1000 LTSR
- Integration of kernel patches due to critical vulnerabilities CVE-2016-3841, CVE-2016-5195, CVE-2017-11176, CVE-2017-17450, CVE-2017-17806, CVE-2017-18079, CVE-2017-18255, CVE-2017-2647, CVE-2017-7273, CVE-2017-8824, CVE-2018-1066, CVE-2018-10840, CVE-2018-10876, CVE-2018-10877, CVE-2018-10880, CVE-2018-10882, CVE-2018-10883, CVE-2018-10938, CVE-2018-1094, CVE-2018-10940, CVE-2018-1095, CVE-2018-1126, CVE-2018-1128, CVE-2018-12232, CVE-2018-14609, CVE-2018-14613, CVE-2018-14625, CVE-2018-14646, CVE-2018-16882, CVE-2018-16884, CVE-2018-17972, CVE-2018-18397, CVE-2018-18445, CVE-2018-18559, CVE-2018-18955, CVE-2018-19407, CVE-2018-20169, CVE-2018-20169, CVE-2018-20764, CVE-2018-20784, CVE-2018-6555, CVE-2018-9363, CVE-2019-3701, CVE-2019-3813, CVE-2019-8912, CVE-2019-8980, CVE-2019-9003, CVE-2019-9162, CVE-2019-10124, CVE-2019-10125
- Security patch for glibc due to critical vulnerabilities CVE-2009-5155, CVE-2017-15671, CVE-2018-20796, CVE-2019-9169
- Updated code signing certificates and corresponding certificate chain
- VMware Horizon client icons have been updated to the new design
- The firmware update process from earlier eLux RP 6 X64 versions with activated package signature verification has been corrected and can be performed without a local factory reset
- Wrong behaviour has been corrected for activating and deactivating the screen saver via keyboard shortcut depending on the configured AD logon method
- If you disable the Shut down user right, the Shut down button of the AD logon dialog will now also be removed
Security updates
Further security updates to fix the Intel and AMD processor vulnerabilities are included in the release of eLux RP 6.5.1000 LTSR. The updates consist of patches for the Linux kernel and processor microcode updates for AMD and Intel chipsets. Unicon strongly recommends that you perform the relevant system updates for your eLux devices. Please note that after updating your devices, appropriate tests in your system environment are necessary to ensure that the desired functionality is still available.
Client Hardware Compatibility List
See Supported Hardware on myelux.com for the client models supported by this version of eLux RP 6.