Scout 15 2507, eLux 7 2507 released

31 Jul 2025

Enhancements of Scout 15 2507

  • OKTA and Entra ID (via OIDC or SAML) are now supported for Scout Board logon. [SBD-1506], [SBD-1543]
  • Upgraded to OpenSSL 3.0.16 to fix the critical vulnerability CVE-2024-13176. [SC-1959]
  • Entra ID added as a new device authentication option for Azure Virtual Desktop (AVD) use cases. [SC-1957]
  • Different MTU sizes can now be configured in the device configuration for wired and WiFi network connections. [SC-1958]
  • Firewall exceptions can now be applied automatically during Scout installation. [SC-1973]
  • The default administrator policy now only allows Scout login with a domain user instead of a local user. [SC-1977]
  • Users' personal settings (filters, sorting, last OU, columns) are now remembered across devices and browsers. [SBD-613]
  • Command history is now accessible directly from the global search. [SBD-1182]
  • OU tree is now searchable with autocompletion and live filtering. [SBD-1414]
  • FollowMe Desktop feature is now supported. [SBD-1511]
  • Predefined images are suggested when assigning images in the device configuration. [SBD-1541]
  • Option to retain local configuration (locked fields) is now available in preferences. [SBD-1550]
  • Database cleanup can now be performed directly from preferences. [SBD-1552]
  • Maximum ping time (device response time) can now be configured in preferences. [SBD-1554]
  • Visual indicators now highlight when an OU overrides configuration; devices can be filtered by this property. [SBD-1567]
  • Devices can now be found using the simple device ID from eLux. [SBD-1571]
  • Peripherals connected to eLux endpoints are now displayed in the properties panel. [SBD-1577]
  • REST API extended with multiple new endpoints. [SBD-1379–SBD-1396]
  • OU meta information (device count, app count, schedules) moved to the properties panel for better performance. [SBD-1505]
  • Various UI/UX enhancements applied across Scout Board. [SBD-1593]

 

Enhancements of eLux 7 2507

  • Avaya Workplace VDI Client 3.0.15.0
  • Cisco Webex VDI Plugin 45.6.1-32593
  • JabraXpress Device Updater 8.5.10-3305
  • uberAgent Client 7.5.0
  • Implemented support for identity providers OKTA and Entra ID using the OpenID Connect (OIDC) protocol. [ELUX-3269]
  • Kernel upgraded to version 6.12.30. [ELUX-4053]
  • Operating system components were updated to incorporate the latest security-related updates and ensure system integrity. [ELUX-3758]
  • Added support for wireless connections using WPA2 Enterprise with PEAP (user credentials). [ELUX-2885]

 

Client Hardware Compatibility

The hardware models supported by this eLux version can be found on myelux.com in the relevant download section under Certified Hardware.

 

Download

Scout 15 2507

eLux 7 2507